Digital
microhmmeter |
||||||||||||||||||||
|
MOM
6-200-01D |
||||||||||||||||||||
| Microohmmeter digital is designed to measure low resistances in the range of 0,01 mO to 400 mOm | ||||||||||||||||||||
| (contact resistance of switches, sockets, fuse blade terminals, bus connections, line connections, etc.) at the | ||||||||||||||||||||
| output 6V voltage and current up to 200A, as well as for the process run these elements. | ||||||||||||||||||||
| Attention! Microhmmeter can be a long time to measure the contact resistance at the output current is 200A, | ||||||||||||||||||||
| which allows the oil to break or an oxide film on the contacts, you can not do microhmmeter low output current, | ||||||||||||||||||||
| or even a short-term high current. | ||||||||||||||||||||
| After the measurement session, all sessions can be viewed on a computer by connecting a cable USB. | ||||||||||||||||||||
|
The measuring rage of resistance and the desired output current is
given from the keyboard. |
||||||||||||||||||||
| By electromagnetic interference (EMI) device complies with EN55022. | ||||||||||||||||||||
|
The device is designed to operate in a temperate climate with
temperature the external environment of |
||||||||||||||||||||
| -20 to +40°C and relative humidity to 80% plus 25°C . | ||||||||||||||||||||
|
Excellent
features of unit:
|
||||||||||||||||||||
| - continuous operation at a maximum current 200A; | ||||||||||||||||||||
| - automatic switching on (off) fans; | ||||||||||||||||||||
| - thermal
protection; |
||||||||||||||||||||
| - highly reliable and fire safe; | ||||||||||||||||||||
| - shock-rugged design that allows measurements in laboratory and on-site. | ||||||||||||||||||||
|
Technical specifications and features of unit: |
||||||||||||||||||||
| - input voltage,V ........................................................................................................................ up 176 to 253; | ||||||||||||||||||||
| - input frequency, Hz ............................................................................................................................. 40-60; | ||||||||||||||||||||
| - output power
(max),
W
.......................................................................................................................
1200; |
||||||||||||||||||||
| - output voltage
(max), V
............................................................................................................................
6; |
||||||||||||||||||||
| - output current, A
.........................................................................................................
10, 20, 50, 100, 200; |
||||||||||||||||||||
| - share factor of
the input current,%
........................................................................................................
0,95; |
||||||||||||||||||||
| - relative
accuracy,%
................................................................................................................................
0,5; |
||||||||||||||||||||
| - efficiency, %, no less ................................................................................................................................ 84; | ||||||||||||||||||||
| - dimensions, mm ...................................................................................................................... 420х330х170; | ||||||||||||||||||||
| - weight, kg, no more .................................................................................................................................. 8; | ||||||||||||||||||||
Measuring ranges (current and resistance)
|
||||||||||||||||||||
|
KP DELTA, 38
Tekstylna st,
Ternopil, Tel /Fax ( +38 0352) 255 852, tel ( +38 0352) 430
386 |
||||||||||||||||||||